🎁 10% off your first order — join with your email👥 Refer a friend — they save, you earn a reward⚡ Ships in 24h from US fulfillment centers · USA · Canada🎁 10% off your first order — join with your email👥 Refer a friend — they save, you earn a reward⚡ Ships in 24h from US fulfillment centers · USA · Canada
2:1 · 2" · 60 ft● LIVE SPEC
UL 224 RecognizedFlame Retardant600V RatedHELIXAL 2:1 Standard Heat Shrink Tubing 2" (50.8mm) — 60ft Roll
BLACK · 2" · 60 FTHELIXAL · ISO 9001
2:1 Single Wall · UL 224 Recognized

2"
2:1 Heat Shrink

FitsMaximum size50.8mm

2 inch heat shrink tubing is the largest standard size made — a 50.8mm expanded bore that slides over the biggest cable bundles, large-diameter pipe and hose, and heavy industrial cable-assembly ends, then recovers to about 25.4mm (1 inch) on full heat. This is the 2:1 single-wall version: UL 224 polyolefin, flame-retardant, 600V, rated −55°C to +125°C. With no adhesive liner it is not waterproof — it is built for mechanical and abrasion protection, UV-resistant covering, and band-marking large bundles in dry-rated environments such as cable trays, MCC panel entries, and outdoor infrastructure. If you need a sealed, watertight sleeve over a 2 inch cable instead, choose the 3:1 dual-wall adhesive-lined version. Supplied as a 60ft bulk roll, cut to length.

★★★★★4.7 · 225 verified ratings across the Helixal range
Only 8 left · Ships in 24h

Order up to 8 online · need more? Trade pricing

Size2" · 50.8mm

Click any size to navigate · 60 ft per roll

$42.4960 ft spool
→ Dispatched within 24 hours — delivered in 1–3 days→ 30-day money-back guarantee — 30 days to return it
Qty
1
Secured by Stripe · No account needed
Trade pricingWholesale →
→Ships USA & Canada
→ISO 9001
→Ships 24h

SKU: B0FJHJZC3F · 2" (50.8mm) · 60 ft

Spec Sheet

2"
data sheet.

High-volume UL 224 Recognized polyolefin at an honest per-foot cost. The industry standard for band marking, bundling, and dry indoor electrical insulation.

Imperial Size
2"
Expanded diameter
Metric Size
50.8mm
Nominal
Roll Length
60 ft
Per spool
Wire Gauge
Maximum size
Bare conductor
Shrink Ratio
2:1
Single wall
Construction
Single Wall
No adhesive liner
Adhesive Liner
None
Not waterproof
Voltage Rating
600V AC
UL 224 — 600 V rms
Temp Rating
-55°C to +125°C
Continuous service
Shrink Temp
100°C (212°F)
Shrinking starts
Material
Polyolefin
UL 224 Recognized
Certification
UL 224
Recognized Component
Flammability
Self-extinguishing
UL 224 Recognized
Color
Black
Standard finish
Moisture
Resistant — not sealed
Single wall only

Sizing over a connector? The Wire Gauge row above is for bare conductor. Heat shrink must be sized to the widest point it passes over, so a crimped butt splice or lug barrel needs a larger tube than the wire alone — a 22–18 AWG splice barrel measures 5–6mm, a 16–14 AWG barrel 7–8mm, and a 12–10 AWG barrel 9–11mm. Measure the barrel, allow about 20% clearance, and confirm the recovered diameter is smaller than the narrowest thing the tube must grip. Use the size calculator.

What the
trade says.

Verified Buyers ★ · Full Range4.7★★★★★225 ratings · 84% 5-starCombined verified-buyer rating for every Helixal product — all ratios, all sizes — not this size alone.
★★★★★

Nice product at great price

Was wiring my car and had quite a few smaller wires to crimp and cover. This worked great — shrinks clean and consistent every time.

Church's · Verified Purchase★ Verified
★★★★★

Perfect for bulk workshop use

Bought this for my automotive workshop and the 120ft roll is exactly what I needed. Shrinks consistently and cleanly every time. Much better value than small packs.

Mike R. · Verified Purchase★ Verified
★★★★★

Professional finish every time

Clean black finish, no bubbles or wrinkles when applied correctly. UL listing is important for commercial electrical work — ticks that box too.

James T. · Verified Purchase★ Verified
Customer Reviews

Loading reviews…

Write a review →
Sizing & Application — 2 inch, 60ft roll

The largest bore in the range, and a 25mm floor underneath it.

2 inch (50.8mm) is the biggest single-wall diameter we stock, recovering to roughly 25.4mm. It goes over heavy cable bundles, hose and pipe, and fully terminated large assemblies. It is also the size most often ordered on the strength of its bore alone, which is half of the specification — the other half is that it will not close onto anything narrower than an inch.

What a 25mm recovered wall can and cannot do

A 50.8mm bore is genuinely useful. It passes over bundles that would need two or three smaller sizes, over hose and pipe up to about 40mm, and over terminated assemblies with boots and glands already fitted. For covering, jacketing and mechanical protection at that scale there is nothing smaller that will do the job.

The constraint is underneath. Recovering to about 25.4mm means the tube stops there, so anything below roughly 27mm is being sleeved rather than fitted. That excludes a great deal of what people intend to use it on: a 4/0 cable at 18–20mm, a typical three-conductor bundle at 20mm, most industrial cable assemblies. The tube goes on, it shrinks, and it still moves.

Where it genuinely fits is on things that are actually large — hose and pipe runs, heavy bundle ends, tray exits, machine cable assemblies with substantial dressing. Before ordering, measure the narrowest thing the tube has to close onto and confirm it is above about 27mm. If it is not, the honest answer is usually 1-1/2 inch or the 3:1 version of this size.

2 inch on the 60ft roll

PropertyFigureWhy it matters
Expanded diameter50.8mm (2")Passes over bundles, hose and pipe up to about 40mm
Recovered diameter≈25.4mmThe floor — nothing below ~27mm is actually gripped
Usable span≈27–40mmWide in absolute terms, narrow relative to the bore
Best applicationsHose and pipe, tray exits, heavy bundle endsThings that are genuinely large, not merely awkward
Wall typeSingle-wall polyolefinCovering, jacketing and abrasion protection; UV resistant
Roll length60 ftMost jobs use two or three 8 in pieces

Ordering by bore alone is the common error at this size. The recovered figure decides whether the finished tube is fitted or merely draped.

When 2 inch 2:1 is not what you want

01 · The item is under about 27mm

It will not be gripped. Use 1-1/2 inch, or the 2" 3:1 Dual Wall whose floor is roughly 16.9mm — three times the closure for the same bore.

02 · The bundle must be sealed

Grooves between conductors stay open end to end under a single-wall tube. Sealed tray exits and enclosure penetrations need the adhesive-lined 3:1.

03 · You need one or two pieces

Sixty feet at this diameter is a substantial roll. If the job is a single penetration, the 2" 3:1 10ft pack is the cheaper way to hold the size.

04 · Above 600V

Our 600V rating is in volts rms, not DC. On a 1000 Vdc circuit the conductor must already be rated and tubing seals or covers rather than insulating.

Keep reading →2" 3:1 Dual Wall — three times the closure · 1-1/2" 2:1 — the next size down · Heat Shrink Tubing Size Chart & Selection Guide

How it shrinks.

01

Measure & Select

Choose a size where the expanded diameter is 20–30% larger than your wire or bundle. Smaller tubes will slide on easier; slightly oversize is better than too tight.

02

Cut & Thread

Cut to length and thread onto the wire before making the splice. The tubing cannot pass over a crimped terminal — position it first, then complete the connection.

03

Apply Heat

The tubing starts shrinking at 100°C — use a heat gun and keep it moving until it has shrunk evenly along its length. Work from the center outward. Avoid open flame — it scorches the tubing and creates uneven shrink.

04

Inspect

Finished tubing should be tight with no bubbles or lifted edges. No adhesive will appear at the ends — this is single-wall tubing. Confirm even recovery across the full length.

✓
Size Reference

Expanded vs.
recovered.

Actual 2" tube at full expanded diameter (50.8mm) and after heat recovery. Use this as your fit reference before cutting.

Expanded: 50.8mm — slides over Maximum size
Shrink ratio: 2:1 on full heat
2" 2:1 heat shrink tubing — expanded diameter 50.8mm versus recovered size reference diagram
2" · 50.8mm expanded2:1 recovery · fits Maximum size

Use it on.

01

Large Cable Bundle Management

Consolidates and protects the largest cable bundles in industrial facilities, data centers, and power distribution environments.

02

Harness Band Marking

Provides large-diameter band identification on industrial wire harnesses for maintenance, commissioning, and future troubleshooting.

03

Pipe & Hose Identification

Identifies pipes, hoses, and conduits in process plants, mining operations, and heavy manufacturing facilities.

04

Panel Entry Strain Relief

Applied at the point where large cable bundles enter panels and enclosures to distribute mechanical stress and prevent jacket wear.

05

Cable Tray Finishing

Provides a clean finished end cap on cable tray bundles at termination points in industrial and commercial electrical installations.

06

Industrial Mechanical Protection

Covers large cable assemblies in environments where abrasion, oil, and mechanical contact are present but submersion is not.

Size Guide

2" Questions.

Cart

Your cart is empty

Add heat shrink tubing to get started.

Shop Products →